中間エネルギー電子分析器 (Medium-Energy Particle Experiments - Electron Analyzer, MEP-e)

MEP-e

担当者

PI

  • 笠原 慧 (東京大学)

Co-PI

  • 横田 勝一郎 (JAXA/ISAS)

参考文献

  • Kasahara, S., K. Asamura, Y. Saito, T. Takashima, M. Hirahara, and T. Mukai, Cusp type electrostatic analyzer for measurements of medium energy charged particles, Review of Scientific Instruments, 77, 123303, doi:10.1063/1.2405358, 2006.
  • Kasahara, S., K. Asamura, K. Ogasawara, Y. Kazama, T. Takashima, M. Hirahara, and Y. Saito, A noise attenuation method for the medium-energy electron measurements in the radiation belt, Advances in Space Research, 43(5), 792-801, 2009.
  • Kasahara, S., T. Takashima, and M. Hirahara, Variability of the minimum detectable energy of an APD as an electron detector, Nuclear Inst. and Methods in Physics Research, A, 664(1), 282-288, 2012.

基本スペック・計測物理量

  • エネルギー範囲: <10 to 80 keV
  • エネルギー分解能: 8% (FWHM)
  • エネルギーステップ: 16 steps per scan
  • センサー視野: 360° (azimuth) × 3.5° (elevation)
  • 検出器の数: 16
  • gファクター: 6.6×10-5 cm2 sr keV/keV per detector
  • 時間分解能: 4 s for full 3-D distribution function

計測原理

静電分析器で入射電子のエネルギー及び飛来方向を分析する。また、検出器としてアバランシェ・フォトダイオード(APD)を用いる。静電分析器で同定したエネルギーと、APDの検出波高を比較する事で、放射線の背景雑音を排除する。

その他の情報